User's Manual
Table Of Contents
- EX-r Series GigE
- Digital Microwave Radios
- Installation and Management Guide
- Legal Notice
- Open-Source License Information
- Table of Contents
- List of Figures
- List of Tables
- About this Document
- Introduction
- Pre-installation Tasks
- Link Engineering and Site Planning
- Familiarization with the EX-r Series GigE Radios
- Initial Configuration and Back-to-Back Bench Test
- Time Division Duplex (TDD) Factors
- Link Orientation and Synchronization
- Radio A/B Configuration
- Radio Synchronization
- Offset Timing
- Virtual Local Area Network (VLAN)
- Simple Network Management Protocol (SNMP)
- System Installation and Initiation Process
- Installation
- Configuration and Management
- Telnet into the Command Line Interface (CLI)
- Telnet
- Exalt Graphical User Interface (GUI)
- Quick Start
- Navigating the GUI
- Radio Information Page
- Administration Settings Page
- Simple Network Management Protocol (SNMP) Configuration
- File Transfer Page
- File Activation Page
- System Configuration Page
- Ethernet Interface Configuration Page
- VLAN Configuration Page
- T1/E1 Configuration Pages
- GPS Information Page
- Alarms Page
- Performance Page
- Event Log Page
- Diagnostic Charts Page
- Spectrum Analyzer Page
- Reboot Page
- Manual Page
- Specifications
- 201872-003Interface Connections
- Antennas
- Troubleshooting
- Back-to-back Bench Testing
- General Compliance and Safety
- Dynamic Frequency Selection
- Safety Notices
- Regulatory Notices
- Regulatory Compliance
- Regulatory Domain Keys
- EIRP Limits for the United States and Canada
- EIRP Limits for Australia
- EIRP Limits for the European Union and ITU Countries
- Declaration of Conformity to the R&TTE Directive 1999/5/EC
- Copyright Notices
- END USER AGREEMENT
- Index
Exalt Installation and Management Guide
EX-r Series GigE Digital Microwave Radios
100 201872-003
2015-10-23
EIRP Limits for the United States and Canada
EX-5r Series EIRP for the US and Canada
5250–5350 MHz Band
For all within the 5250–5350 MHz band, the maximum EIRP is 30 dBm. The maximum output of the
radio is +13 dBm.
P = 30 – G + L
where:
5470–5725 MHz Band
For all models within the 5470–5725 MHz band, the maximum EIRP allowed is 30 dBm. The
maximum output power of the radio is +13 dBm.
P = 30 – G + L
where:
5725–5850 MHz Band
For all models within the 5725–5850 MHz band, the maximum EIRP allowed is 61.9 dBm. The
maximum output power of the radio is +24 dBm in Mode 1 and +21 dBm in Mode 2.
P = 61.9 – G + L
where:
Note: The professional installer is responsible to ensure that RF output power is properly
adjusted to not exceed the regulatory limit.
P = Maximum transmitter output power of radio, in dBm.
G = Specified gain of antenna, in dBi, from 5250 to 5350 MHz.
L = Total transmission system losses of all elements between the radio’s RF connector and the
antenna’s RF connector (all cables, connectors, lightning suppressors), in dB, as specified
or measured between 5250 and 5350 MHz.
P = Maximum transmitter output power of radio, in dBm.
G = Specified gain of antenna, in dBi, from 5470 to 5725 MHz.
L = Total transmission system losses of all elements between the radio’s RF connector and the
antenna’s RF connector (all cables, connectors, lightning suppressors), in dB, as specified
or measured between 5470 and 5725 MHz.
P = Maximum transmitter output power of radio, in dBm.
G = Specified gain of antenna, in dBi, from 5725 to 5850 MHz.
L = Total transmission system losses of all elements between the radio’s RF connector and the
antenna’s RF connector (all cables, connectors, lightning suppressors), in dB, as specified
or measured between 5725 and 5850 MHz.