User's Manual

Table Of Contents
Exalt Installation and Management Guide
EX-i Series (TDD) Digital Microwave Radios
8 206501-019
2016-05-24
Inspect the outer packaging and the contents of the boxes upon receipt. If you suspect any shipping
damage or issues with the contents, contact Exalt Customer Care.
Initial Configuration and Back-to-Back Bench Test
Every Exalt digital microwave radio goes through extensive quality testing and performance
evaluation over the full operating temperature range prior to shipment. However, before installation, it
is strongly advised to perform several tests and tasks that are much more difficult to perform once the
radio link endpoints are distant from one another. A back-to-back bench test and pre-configuration will
provide confidence that the radio link is operational and properly configured prior to installation, so
that if troubleshooting is necessary, the radio hardware and configuration settings are eliminated from
the troubleshooting process. Verify the following in the back-to-back testing:
Confirm that the radio system is generally operational
Radios power-up with planned power and wiring solutions
Regulatory Domain Key (RDK) entry successful
RF link connects in both directions
Traffic passes across the link
Configure connected equipment and cabling
Test Ethernet (CAT5) cabling, and/or T1/E1 cabling, any auxiliary connector cabling and
configure all interfaces
Configure IP settings for configuration and management
Configure passwords and security modes
Become familiar with the configuration and management interfaces through the Exalt GUI
interface
Configure radio parameters, including installing any optional software license keys and
configuring features controlled by license keys
Set transmitter output power to engineered or allowed level (see RF Output Power Setting
)
Set operating center frequency
Note: Register your system as soon as possible. A 2-year Warranty period applies to products
registered within 90 days of purchase. The Warranty period is reduced to 1-year for
unregistered products and products registered after the first 90 days. See Exalt Limited
Hardware Warranty.
Note: Exalt radios with the RDK function are DISABLED when initially shipped. To
ENABLE the radio, a valid RDK must be entered on the Administration Settings Page
of the
Exalt GUI. The RDK references the unit's serial number and is provided based on the country
and/or region where the radio system will be deployed. The RDK is obtained through your
Exalt Authorized distributor or reseller.
Note: Some countries require Dynamic Frequency Selection (DFS), which delays the
transmitter turn-on time during the initial Clear Channel Assessment period of 1 minute. In
accordance with these regulations, the radios boot up, and then wait for 1 minute before
linking.