User's Manual

Table Of Contents
Exalt Installation and Management Guide
EX-i Series (TDD) Digital Microwave Radios
122 206501-019
2016-05-24
EIRP Limits for the European Union and ITU Countries
The countries that are covered by this Regulatory Domain are: Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Ghana, Great Britain, Greece, Hungary,
Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Norway, Poland,
Portugal, Slovak Republic, Slovenia, Spain, Sweden, Netherlands, Switzerland, and Turkey.
Use only parabolic dish antennas or directional flat-panel antennas. No other types of antennas
(omni-directional, yagi, and so on) are authorized. Parabolic dishes of either grid or solid type are
allowed. Maximum mid-band gain of each type of antenna certified is:
EX-2.4i models:
Parabolic dish: 30.3 dBi (6'/1.8m diameter)
Directional flat panel: 20.5 dBi (~2'/61cm square)
–EX-5i models:
Parabolic dish: 37.9 dBi (6'/1.8m diameter)
Directional flat panel: 28 dBi (~2'/61cm square)
EX-2.4i-Series EIRP
For EX-2.4i models within the 2400–2483.5 MHz band, the maximum EIRP allowed is summarized in
Table 14. The maximum output power of the radio is +27dBm in Mode 1 and +24dBm in Mode 2.
P = ME – G + L
where:
Note: The professional installer is responsible to ensure that RF output power is properly
adjusted to not exceed the regulatory limit.
P = Maximum transmitter output power of radio, in dBm.
ME = Maximum EIRP, as specified in Table 14.
G = Specified gain of antenna, in dBi, from 2400 to 2483.5 MHz.
L = Total transmission system losses of all elements between the radio’s RF connector and
the antenna’s RF connector (all cables, connectors, lightning suppressors), in dB, as
specified or measured between 2400 and 2483.5 MHz.
Table 14 EU and ITU Country-Specific EIRP Levels for the EX-2.4i Series
Country Maximum EIRP
Austria 20 dBm
Belgium 20 dBm
Cyprus 20 dBm
Czech Republic 20 dBm
Denmark 20 dBm
Estonia 20 dBm
Finland 20 dBm