User's Manual
Table Of Contents
- EX-i Series (TDD)
- Digital Microwave Radios
- Installation and Management Guide
- Legal Notice
- Open-Source License Information
- Table of Contents
- List of Figures
- List of Tables
- About this Document
- Introduction
- Pre-installation Tasks
- Link Engineering and Site Planning
- Familiarization with the i-Series Radios
- Initial Configuration and Back-to-Back Bench Test
- RF Output Power Setting
- Time Division Duplex (TDD) Factors
- Link Orientation and Synchronization
- Radio Synchronization
- Offset Timing
- Virtual Local Area Network (VLAN)
- Link Symmetry
- Simple Network Management Protocol (SNMP)
- System Installation and Initiation Process
- Installation
- Configuration and Management
- Command Line Interface (CLI)
- Telnet into the Command Line Interface (CLI)
- Exalt Graphical User Interface (GUI)
- Quick Start
- Navigating the GUI
- Radio Information Page
- Administration Settings Page
- Simple Network Management Protocol (SNMP) Configuration
- File Transfer Page
- File Activation Page
- Access Security Page
- System Configuration Page
- MHS Configuration Page
- Ethernet Interface Configuration Page
- VLAN Configuration Page
- T1/E1 Configuration Pages
- DS3 Configuration Page
- GPS Information Page
- Alarms Page
- MHS Status Page
- Performance Page
- Event Log Page
- User Throughput Page
- Diagnostic Charts Page
- Spectrum Analyzer Page
- Ethernet Utilization Page
- Reboot Page
- Manual Page
- Specifications
- Interface Connections
- DIP Switch Settings (-16 Models Only)
- Antennas
- DC Coupler for Antenna Alignment
- Troubleshooting
- Back-to-back Bench Testing
- General Compliance and Safety
- Dynamic Frequency Selection
- Safety Notices
- Regulatory Notices
- Regulatory Compliance
- Regulatory Domain Keys
- EIRP Limits for the United States and Canada
- EIRP Limits for the European Union and ITU Countries
- EIRP Limits for Australia
- Declaration of Conformity to the R&TTE Directive 1999/5/EC
- END USER AGREEMENT
- Copyright Notices
- Index
Exalt Installation and Management Guide
EX-i Series (TDD) Digital Microwave Radios
206501-019 113
2016-05-24
Regulatory Notices
This section presents the Regulatory Compliance Regulations for your country.
4.9GHz Model
The EX-4.9i is a licensed-band product operating within Part 90 of the FCC regulations and RSS-111
of Industry Canada. These bands are specifically reserved for Public Safety applications and related
agencies, in accordance with these regulations.
Transmitter power reduction may be required, depending on transmission system gains and losses, in
accordance with instructions found in this appendix.
The transmitter power of the device must be reduced by 1 dB for every 1 dB that the antenna gain
exceeds 26 dBi (inclusive of transmission system losses).
United States Compliance
The EX-2.4i and EX-5i product families operate under FCC Rule Parts 15.247 and/or 15.407 as a
license-exempt device. The EX-4.9i products operate under FCC Rule Part 90 as a licensed device.
They may only be used as a point-to-point transmission device for fixed or temporary-fixed (non-
mobile) installations. The devices are subject to the following restrictions:
• Do not use external amplifiers to boost the power or overcome transmission system losses, unless
the specific amplifier/cable/antenna combination has expressly been authorized by the FCC. The
output power must never exceed +30 dBm.
• Cross-border transmissions are expressly prohibited, except with written permission from both the
FCC and the governing body of the neighboring country (Cofetel for Mexico; Industry Canada for
Canada).
• Use only parabolic dish antennas or directional flat-panel antennas. No other types of antennas
(omni-directional, yagi, and so on) are authorized. Parabolic dishes of either grid or solid type are
allowed. Maximum mid-band gain of each type of antenna certified is:
– EX-2.4i models:
– Parabolic dish: 30.3 dBi (6'/1.8m diameter)
– Directional flat panel: 20.5 dBi (~2'/61cm square)
– EX-4.9i models:
– Parabolic dish: 26dBi (larger gains are allowed, with Tx power reduction)
– Directional flat panel: 26 dBi (larger gains are allowed, with Tx power reduction)
–EX-5i models:
– Parabolic dish: 37.9 dBi (6'/1.8m diameter)