User's Manual
Table Of Contents
- EX-i Series (TDD)
- Digital Microwave Radios
- Installation and Management Guide
- Legal Notice
- Open-Source License Information
- Table of Contents
- List of Figures
- List of Tables
- About this Document
- Introduction
- Pre-installation Tasks
- Link Engineering and Site Planning
- Familiarization with the i-Series Radios
- Initial Configuration and Back-to-Back Bench Test
- RF Output Power Setting
- Time Division Duplex (TDD) Factors
- Link Orientation and Synchronization
- Radio Synchronization
- Offset Timing
- Virtual Local Area Network (VLAN)
- Link Symmetry
- Simple Network Management Protocol (SNMP)
- System Installation and Initiation Process
- Installation
- Configuration and Management
- Command Line Interface (CLI)
- Telnet into the Command Line Interface (CLI)
- Exalt Graphical User Interface (GUI)
- Quick Start
- Navigating the GUI
- Radio Information Page
- Administration Settings Page
- Simple Network Management Protocol (SNMP) Configuration
- File Transfer Page
- File Activation Page
- Access Security Page
- System Configuration Page
- MHS Configuration Page
- Ethernet Interface Configuration Page
- VLAN Configuration Page
- T1/E1 Configuration Pages
- DS3 Configuration Page
- GPS Information Page
- Alarms Page
- MHS Status Page
- Performance Page
- Event Log Page
- User Throughput Page
- Diagnostic Charts Page
- Spectrum Analyzer Page
- Ethernet Utilization Page
- Reboot Page
- Manual Page
- Specifications
- Interface Connections
- DIP Switch Settings (-16 Models Only)
- Antennas
- DC Coupler for Antenna Alignment
- Troubleshooting
- Back-to-back Bench Testing
- General Compliance and Safety
- Dynamic Frequency Selection
- Safety Notices
- Regulatory Notices
- Regulatory Compliance
- Regulatory Domain Keys
- EIRP Limits for the United States and Canada
- EIRP Limits for the European Union and ITU Countries
- EIRP Limits for Australia
- Declaration of Conformity to the R&TTE Directive 1999/5/EC
- END USER AGREEMENT
- Copyright Notices
- Index
Exalt Installation and Management Guide
EX-i Series (TDD) Digital Microwave Radios
206501-019 97
2016-05-24
There are several scenarios for using the DIP switches. Figure 9 describes common configurations and
related applications.
Link Distance <10 miles
Bandwidth 8 MHz
Mode Mode 1
TDD Frame Size 2ms
Ethernet Interfaces Enabled, 100/Full
AUX port NMS Access In-Band
T1/E1 Settings All Enabled, T1, B8ZS, AIS
Table 9 Common DIP Switch Applications
Application Switch Positions Comments
Reset all critical factory defaults 0xxxxxxx If the IP address and/or passwords are forgotten
or lost, use this setting and execute the critical
reset procedure (RMT button held through boot
cycle).
Reset complete factory defaults
except for IP information and
passwords
1x00xxxx If the IP address and/or passwords are already
reset or are known but the configuration of the
radio parameters is unknown, use this setting to
restore all parameters to factory defaults.
Execute the critical reset procedure with these
settings. If trying to establish a link, configure
one radio as Radio A, the other as Radio B using
position 2.
Configure the radio as Radio A
while resetting.
11xxxxxx Choose the desired reset function using position
4. Reset one radio as Radio A with position 2
up, so that a link can be established.
Change TDM interfaces to E1 1x1xxxxx Choose the desired reset function using position
4. Reset both radios with position 3 up to
configure E1 at each end. One radio must be
Radio B, and the other Radio A (using position
2).
Configure for ideal antenna
alignment configuration
1xx1xxxx Reset the radio with position 4 up to configure
for the best setting to optimize antenna
alignment. One radio must be configured as
Radio A, the other as Radio B (using position 2).
Table 8 Standard Factory Defaults (-16 Models) (Continued)
Parameter EX-2.4i-16 EX-5i-16