User's Manual

Table Of Contents
Exalt Communications, Inc.
Exalt i-Series Installation and Management Guide
5000001 59
2007-04-15
Manufacturer Model # Description Mid-band Gain dBi
(mid-band)
3dB (Azimuth/Elevation) Beamwidth
(degrees)
MTI MT-485001 7.5-inch Panel 19.0 18.0
MTI MT-485002 1-foot Panel 23.0 9.0
MTI MT-486004 18-inch Panel 26.0 6.0
MTI MT-486001 2-foot Panel 28.0 4.5
Radio Waves FP.5-5-18 6-inch Panel 18.0 20.0
Radio Waves FP1-5-24 1-foot Panel 23.8 10.0
Radio Waves FP2-5-28 2-foot Panel 28.0 4.5
Radio Waves SP1-5.2 1-foot Dish 22.5 11.1
Radio Waves SP2-5.2 2-foot Dish 29.0 6.1
Radio Waves HP2-5.2 2-foot HP Dish 28.6 6.1
Radio Waves SP3-5.2 3-foot Dish 32.0 4.0
Radio Waves SP4-5.2 4-foot Dish 34.8 3.0
Radio Waves SP6-5.2 6-foot Dish 37.9 2.0
RFS SPF2-52A 2-foot Dish 27.9 6.2
RFS SPF3-52A 3-foot Dish 31.4 4.2
RFS SPF4-52A 4-foot Dish 33.9 3.1
RFS SPF6-52A 6-foot Dish 37.4 2.1
RFS SDF4-52A 4-foot HP Dish 33.9 3.1
RFS SDF6-52A 6-foot HP Dish 37.4 2.1
RFS MA0528-19AN 7.5-inch Panel 19.0 18.0
RFS MA0528-23AN 1-foot Panel 23.0 9.0
RFS MA0528-28AN 2-foot Panel 28.0 4.5
Initial Antenna Mounting
The antenna must be an exact model recommended by the path and site planning
engineer(s). Mount the antenna at the proper height, mast/mounting location and
polarization orientation as determined by the path and site planning engineer(s). The
model type, location, and orientation of the antenna is critical with respect to achieving
proper path clearance, as well as to mitigate external or self-interference from nearby or
collocated systems operating in or near the same frequency band.
Warning: Mount the antenna in a restricted area and in a manner
preventing long-term human exposure to the transmitted RF energy. To
comply with FCC and Industry Canada regulations, the minimum safe
distance from the antenna for continuous human exposure for the EX-2.4i
models is 10 feet (3m), 39 inches (1m) for the EX-4.9i, and 10.5 feet
(3.2m) for the EX-5i models.