User's Manual
Exalt Communications, Inc.
r-series Installation and Management Manual
5000007 (ETSI) 16
2007-02-12 (draft)
Parameter EX-4.9r Series EX-5r Series
Link Security Key 000000000000
Administration Password password
User Password password
IP Address 10.0.0.1
IP Mask 255.0.0.0
IP Gateway 0.0.0.0
Ethernet Interface Alarm Enabled, 100/Full
T1/E1 Enabling All Disabled
In many cases, the system design will not be identical to the factory default
configuration, and in some cases, these differences prohibit the installation of the
radio. If at all possible, obtain a computer and configure the radio terminals using
the browser-based GUI. See Exalt Graphical User Interface (GUI) on page 35 for
details.
Radio Reset
Use the reset function if the IP address and/or passwords are lost. Use the following steps to
perform a critical parameter reset:
1. Remove power from the radio by disconnecting the AC adapter from the power injector.
2. Hold down RESET button on the power injector while applying power.
Hold the RESET button down through the entire power cycle and monitor the
DATA+POWER left LED on the power injector. Release the RESET button only after the
LED is in the steady state (45 to 60 seconds).
3. Release the RESET button.
The following configurations are reset on the radio:
• IP address = 10.0.0.1
• IP mask = 255.0.0.0
• IP gateway = 0.0.0.0
• Administration password = password
• User password = password
• Endpoint Identifier = Radio B