User guide
EXACOM VCR-2020
Copyright 1991, 92, 93, 94, 95, 96 all rights reserved by EXACOM, Inc.
21
Be sure to check the display when adjusting the time. Seconds are always set to 00,
and the time is entered into the system when SUPV is pressed. To exit the TIME SET
mode without changing the system time, turn the Supervisor Key off.
3.5.0 DATE SET Mode
This mode allows setting of the real-time clock date. The mode is selected by pressing
the STOP button three times once the Supervisor Key has been turned on.
Figure 15: Supervisor DATE SET Display
The FREV button sets the Month, the FFWD button sets the Day and the PLAY button
sets the year (1989 - 2089). Pressing each button increments, then cycles the setting.
The first time a button is pressed, the current date is "copied" from the top line to just
above the labels, and the new time will be entered into the system once the SUPV
button is pressed. To exit without changing the date, turn the Supervisor Key off.
3.6.0 IDLE Mode
This mode can be selected if the console is placed in MONITOR mode and no activity
is taking place at the selected console. IDLE mode can be exited by pressing STOP, or
pressing the FREV button to enter MESSAGE SEARCH mode.