Specifications
EXACOM VCR-2020
Copyright 1991, 92, 93, 94, 95, 96 all rights reserved by EXACOM, Inc.
25
4) VOR/VOX requires some additional switch manipulation to insure correct
execution of desired ATTACK and HOLD times.
a)ATTACK time is the amount of time required for verification of valid
audio signals. ATTACK time is adjusted through two switches which
present four different ATTACK time settings. (SW2, Switch 3 and 4.)
ATTACK ON TIMES Switch 3 Switch 4
0.000 sec. OFF OFF
0.124 sec. ON OFF *
0.250 sec. OFF ON
0.475 sec. ON ON
* NOTE: Use this setting for adjusting VOX level.
b) HOLD time is adjusted using three switches which present
eight different HOLD time settings. (SW2 Switches 5, 6 and 7.)
HOLD (OFF) TIMES Switch 5 Switch 6 Switch 7
VOX Deactivated OFF OFF OFF
4 sec. ON OFF OFF *
6 sec. OFF ON OFF
8 sec. ON ON OFF
12 sec. OFF OFF ON
16 sec. ON OFF ON
24 sec. OFF ON ON
32 sec. ON ON ON
* NOTE: Use this setting for adjusting VOX level.
c) Test for proper record operation. Audio RECORD, no audio
IDLE (after ATTACK and HOLD times).