C) LOOP CURRENT START: (Two wire configuration)
This mode will only record activity on phones that are in line after the VCR-
2020 Console. The telephone line must pass through the console, therefore this
configuration is most effectively used when the console is "co-located" with the
phone to be recorded.
1) On SW1, set switch 3 to the ON position. Set switches 1 and 2 to the OFF
position.
2) Connect a standard phone cable (RJ11) from a phone jack into the VCR-2020
Console at the jack labeled LINE.
3) Connect another RJ11 cable from a phone into the VCR-2020 Console
at the jack labeled PHONE.
4) Test for proper record operation. Off-hook RECORD, on-hook IDLE.
Figure 6: Console Rear Panel Connections for Loop Current Start