Specifications

EXACOM VCR-2020
Copyright 1991, 92, 93, 94, 95, 96 all rights reserved by EXACOM, Inc.
18

4.30 VCR-2020 Installation
4.31 Component Checklist
VCR-2020 Server
VCR-2020 Interface Ports (Cards)
VCR-2020 Console(s) (Rack or Desk Top version)
VCR-2020 Console Key(s) (one per Console)
4.32 Installation Procedure
4.32.1 Set up the Server
Install the interface card(s)
If the interface card(s) are not already installed in the VCR-2020 Server the
switch settings on the card will have to be set as follows:
Card Switches
Position 1 2 3 4 5 6 7
1 OFF OFF OFF OFF ON OFF OFF
2 OFF OFF ON ON OFF ON OFF
3 OFF ON OFF ON ON ON OFF
4 OFF ON ON ON OFF OFF ON
5 ON OFF OFF ON ON OFF ON
Select the AC Power voltage at switch near power cord socket on rear of
chassis.
Connect the power cord from the rear of the Server to an AC outlet.
Connect an RJ22 (handset size) communications cable to a port on an
interface card at the rear of the Server:
Connect one cable per VCR-2020 Console. The lowest port on the
VCR-2020 interface card corresponds to the lowest console
position on the card. Always start with the lowest port on the
lowest numbered card and work up to the highest card and port.
4.32.2 Console Communications Connections
Connect the free end of the RJ22 communications cable to the RJ22 jack on
the rear of the console labeled COMM.