Operating instructions

9-6
SCSI REFERENCE 1012975
CHAPTER 9—MODE SELECT (15h)
First Storage Element Address – Bytes 06 and 07
This field identifies the starting address of the cartridge storage locations. The
default starting address is 01h (1). When assigning new addresses, you assign
the first number and the autoloader automatically assigns the others
sequentially.
Number of Storage Elements – Bytes 08 and 09
This field identifies the maximum number of cartridge storage locations within
the autoloader. The maximum valid value for this field is 07h (7).
The number of storage elements is fixed and cannot be changed using the
MODE SELECT command. See the Magnum 1x7 LTO Autoloader Product
Manual for more information about limiting the number of cells used by the
autoloader.
Note: If both the Fixed Cleaning Cell and Auto-Clean flags are set to 1 on the
Cleaning Configuration Page (see page 9-12) and the InvACIn bit on the
Unique Properties Page (see page 9-9) is set to 1, the cell with the highest
address may not be available to SCSI. In this case the maximum number of
storage elements is six and the value for this field is 06h.
First Import/Export Element Address – Bytes 10 and 11
This field identifies the address of the entry/exit port. The autoloader does not
have an entry/exit port. The value for this field must be 0.
Number of Import/Export Elements – Bytes 12 and 13
This field identifies the total number of locations used for importing and
exporting cartridges to and from the cartridge storage areas. The autoloader
does not have an entry/exit port. The value for this field must be 0.
First Data Transfer Element Address – Bytes 14 and 15
This field identifies the starting address of the installed tape drive. The
autoloader has only one tape drive with a default address is 52h (82).
Number of Data Transfer Elements – Bytes 16 and 17
This field identifies the number of tape drive installed in the autoloader. The
autoloader has only one tape drive. The valid value for this field is 0 or 1.
Note: The actual number of tape drives installed cannot be changed by this field
because the autoloader automatically determines the number of tape
drives during power-up. It is not an error to specify a value that is different
from the actual number of tape drives installed, as long as that value is 0 or
1. If the value is not 0 or 1, the autoloader returns Check Condition status
with the sense key set to Illegal Request.