WHAT YOU SEND TO THE AUTOLOADER
Page Code – Byte 00, Bits 5 through 0
This field identifies the Element Address Assignment page. The value of this
field must be 1Dh.
Page Length – Byte 01
This field indicates the length, in bytes, of the Element Address Assignment
parameter list. The valid value for this field is 12h (18), which indicates that
there are an additional 18 bytes of parameter data that follow this byte.
Medium Transport Element Address – Bytes 02 and 03
This field identifies the address of the cartridge loader. The default value for
this field is 56h (86).
Number of Medium Transport Elements – Bytes 04 and 05
This field identifies the number of cartridge loaders within the autoloader. The
autoloader has only one cartridge loader. The valid value for this field is 1.
Bit
Byte
7 6 5 4 3 2 1 0
00 Reserved Page Code (1Dh)
01 Page Length
02 (MSB)
Medium Transport Element Address
(LSB)
03
04 (MSB)
Number of Medium Transport Elements
(LSB)
05
06 (MSB)
First Storage Element Address
(LSB)
07
08 (MSB)
Number of Storage Elements
(LSB)
09
10 (MSB)
First Import/Export Element Address
(LSB)
11
12 (MSB)
Number of Import/Export Elements
(LSB)
13
14 (MSB)
First Data Transfer Element Address
(LSB)
15
16 (MSB)
Number of Data Transfer Elements
(LSB)
17
18
Reserved
19