Operating instructions

SEPTEMBER 2005 MAGNUM 1X7 LTO AUTOLOADER
9-1
9
MODE SELECT (15h)
9.1 ABOUT THIS COMMAND
The MODE SELECT command enables you to specify operating parameters
for the autoloader. These parameters configure the autoloader upon power-up
or a reset condition. You provide the parameters in a parameter list that can
include the following:
4 bytes for the Parameter List Header (required)
20 bytes for the Element Address Assignment page
6 bytes for the Unique Properties page
36 bytes for the LCD Mode page
4 bytes for the Cleaning Configuration page
Bit
Byte
7 6 5 4 3 2 1 0
00 00010101
01 Reserved PF Reserved SP
02
Reserved
03
04 Parameter List Length
05 00 Reserved 00
!
! !
! Important
The values sent to the autoloader apply to all initiators in a
multi-initiator environment. If an initiator issues a MODE SELECT
command that changes any current or saved operating parameters,
the autoloader returns a Check Condition status with a sense key of
Unit Attention (6h) and an ASC and ASCQ of Mode Parameters
Changed (2Ah and 01h, respectively) to all other initiators that
issue a request to the autoloader.