Operating instructions
SEPTEMBER 2005 MAGNUM 1X7 LTO AUTOLOADER
7-1
7
LOG SELECT (4Ch)
7.1 ABOUT THIS COMMAND
The LOG SELECT command allows you to reset the statistical information
maintained by the autoloader to zero. The LOG SELECT command does not
transfer any parameters to the autoloader and does not include any parameter
pages.
7.2 WHAT YOU SEND TO THE AUTOLOADER
Byte 01, Bit 1 – PCR (Parameter Code Reset)
This field specifies whether the autoloader should reset all of the parameters
or only selected parameters, as follows:
0 – Do not reset any parameters.
1 – Reset all of the parameters.
Note: If you set the PCR bit to 1, be sure that the Parameter List Length is 0.
Otherwise, the autoloader will return Check Condition status with the
sense key set to Illegal Request (5h), the ASC and ASCQ set to 24h and
00h.
SP (Saved Page) – Byte 01, Bit 0
The autoloader does not support the saved page function. The valid value for
this field is 0.
Bit
Byte
7 6 5 4 3 2 1 0
00 01001100
01 Reserved PCR SP
02
Reserved
…
08
09 00 Reserved 00