Operating instructions
SEPTEMBER 2005 MAGNUM 1X7 LTO AUTOLOADER
5-5
COMMAND STATUS
Check Condition
Check Condition status is returned for the following reasons:
The message system is enabled and a message error occurs while the
autoloader is processing the command.
The autoloader detects a parity error while receiving the CDB and the
message system is not enabled.
A Unit Attention condition is pending for the initiator.
The autoloader has experienced an unrecoverable hardware error.
The autoloader encounters a problem while scanning the cartridges.
The autoloader is not ready because the cartridge access port door is open.
A parameter in the CDB is invalid (see Ta b l e 5 - 4 for sense data).
Table 5-4 I
nvalid parameters in the INITIALIZE ELEMENT STATUS WITH RANGE CDB
Sense
Key
ASC ASCQ
SKSV
Bit
C/D
Bit
BPV
Bit
Bit
Pointer
Field
Pointer
Error
5h 24h 00h 1 1 1 — —
A reserved bit is set in the CDB. The
pointers point to the bit in error.