Operating instructions

4-4
SCSI REFERENCE 1012975
CHAPTER 4—INITIALIZE ELEMENT STATUS (07h)
4.4 COMMAND STATUS
The autoloader returns a status byte after processing the INITIALIZE
ELEMENT STATUS command as follows:
Good
The autoloader returns Good status when it is able to process the command
without errors.
Busy
The autoloader returns Busy status when it is processing a command for a
different initiator or when it is in the process of aborting a motion command.
Reservation Conflict
The autoloader returns Reservation Conflict status when it or the cartridge
loader is reserved by a different initiator. See Chapter 20 for more information
about the RESERVE command.
Check Condition
Check Condition status is returned for the following reasons:
The message system is enabled and a message error occurs while the
autoloader is processing the command.
The autoloader detects a parity error while receiving the CDB and the
message system is not enabled.
A Unit Attention condition is pending for the initiator.
The autoloader has experienced an unrecoverable hardware error.
The autoloader encounters a problem while scanning the cartridges.
The autoloader is not ready because the cartridge access port door is open.
A parameter in the CDB is invalid (see Ta b l e 4 - 4 for sense data).
Table 4-4 I
nvalid parameters in the INITIALIZE ELEMENT STATUS CDB
Sense
Key
ASC ASCQ
SKSV
Bit
C/D
Bit
BPV
Bit
Bit
Pointer
Field
Pointer
Error
5h 24h 00h 1 1 1
A reserved bit is set in the CDB. The
pointers point to the bit in error.