Operating instructions
SEPTEMBER 2005 MAGNUM 1X7 LTO AUTOLOADER
4-3
EFFECTS ON THE CARTRIDGE INVENTORY
A request is made to check for the presence of a cartridge in a storage
location and the operation completed successfully. See Ta b l e 4 - 2 for more
information about how the cartridge inventory is updated.
A request is made to scan a cartridge in a storage location and the operation
failed because the bar code scanner was unable to read the label on the
cartridge or if the cartridge does not have a label. The scan will not fail if the
location is empty. See Ta b l e 4 - 3 for details about how the cartridge inventory
is updated.
Table 4-2 Effect on the cartridge inventory of a request to check the occupied status of a storage location
This cartridge inventory field...
... is changed to the following when...
... the location is empty ... the location is full
Occupied 0 1
Occupied Valid 1 1
Label blanks no change
Label Valid 0 no change
Label Scan Retries 0 no change
Source Storage Element Address no change no change
Table 4-3 Effect on the cartridge inventory when a request for a cartridge scan fails
This cartridge inventory field...
...is changed to the following when the autoloader cannot read
the cartridge label
Occupied 1
Occupied Valid 1
Label blanks
Label Valid 0
Label Scan Retries updated if retried
Source Storage Element Address no change