Operating instructions
SEPTEMBER 2005 MAGNUM 1X7 LTO AUTOLOADER
4-1
4
INITIALIZE ELEMENT
STATUS (07h)
4.1 ABOUT THIS COMMAND
The INITIALIZE ELEMENT STATUS command causes the autoloader to
attempt reading any bar code labels that were unreadable during the
automatic cartridge inventory. The autoloader checks the elements in
ascending element address order (see Section 2.2 on page 2-2 for more
information about element addresses). The information obtained by this
command can be returned to the initiator using the READ ELEMENT STATUS
(B8h) command. For specific information about the time required to complete
this command, refer to the Magnum 1x7 LTO Autoloader Product Manual.
Notes:
Support for the INITIALIZE ELEMENT STATUS command is provided for
compatibility. The autoloader automatically re-establishes the cartridge
inventory immediately after power-on or whenever the cartridge access port
door is opened, then closed again. Issuing a INITIALIZE ELEMENT STATUS
command causes the autoloader to attempt reading any bar code labels that
were unreadable during the most current inventory operation.
For specifications for the bar code labels that can be used with the autoloader,
refer to the Exabyte Bar Code Label Specification for LTO Ultrium Cartridges.
Bit
Byte
7 6 5 4 3 2 1 0
00 00000111
01 Reserved
02
Reserved
03
04
05 NBL Reserved