ERRORS REPORTED OVER THE SCSI BUS
00h 2Ah 01h 6h I 10, 11 Mode parameters changed. Mode
parameters have been changed. Issue a
MODE SENSE (1Ah) command to
determine what the new mode
parameters are.
00h 2Ah 02h 6h I 10, 11 Log parameters changed. Log
parameters have been changed. Issue a
LOG SENSE (4Dh) command to
determine what the new log parameters
are.
00h 3Fh 01h 6h I 10 Microcode changed. New microcode
was loaded.
00h 3Fh 03h 6h I 10 Inquiry data has changed. Data in the
Standard Inquiry Page has been altered.
Issue an INQUIRY (12h) command to
determine what the new Inquiry Data.
Compare the Standard Inquiry Data Page
to the The Original Data Page (Page
Code C0h) to determine what changed.
Note: Changes to the Standard Inquiry
data may make it necessary to
reload drivers.
00h 5Bh 01h 6h I 11 Threshold condition met. Log threshold
met. (For additional information about
this error, look at the Log Parameter Page
Code and Log Parameter Code bytes in
the REQUEST SENSE data.)
00h 5Bh 02h 1h I 11 Log counter at max. Log parameter
overflow. (A cumulative counter reached
its maximum value of all FFs.)
00h 5D FFh 6h T, L, D 11 TapeAlert exception. This error is a result
of any of the following:
An autoloader component has
exceeded its expected operational
lifetime.
TapeAlert asynchronous notification.
TapeAlert asynchronous notification
test.
02h 4Eh 00h Bh B, L,
D, S, A
8, 11,
12, 13
Overlapped commands attempt.
Overlapped commands attempted. Bad
initiator-target-LUN (ITL) nexus.
Table A-3 REQUEST SENSE error information (FSC, ASC, ASCQ, and SK (continued)
FSC
ASC
(byte 12)
ASCQ
(byte 13)
Sense
Key
Cause ERP SCSI Error Message and Description