ERRORS REPORTED OVER THE SCSI BUS
5D FFh 00h 6h T, L, D 11 TapeAlert exception. This error is a result
of any of the following:
An autoloader component has
exceeded its expected operational
lifetime.
TapeAlert asynchronous notification.
TapeAlert asynchronous notification
test.
83h 00h T, L 14, 16,
12
Bad label. Questionable.The bar code
label is questionable. Issue an INITIALIZE
ELEMENT STATUS (07h or E7h) command
to reread the label.
83h 01h T, L 14, 16,
12
Bad Label. Unreadable. Cannot read bar
code label.
83h 03h T, L 14, 16,
12
Bad Label. Full Question. Label and full
status questionable. The autoloader was
powered on or the cartridge access port
door was opened. The cartridge inventory
may have been violated. Issue an
INITIALIZE ELEMENT STATUS (07h or
E7h) command to reestablish the cartridge
inventory.
83h 09h O, T 10, 16,
12
Bad Label. No Label. The bar code
scanner could not read the bar code label
because there was no label on the
cartridge or the label was unreadable.
83h 0Ah L 12 Bad Label. Hardware Error. The
autoloader is unable to read the bar code
label due to a bar code reader hardware
error.
87h 21h 1Bh 4h D, L 8, 13, 12 Drive comm failed. The autoloader is
unable to communicate with the tape
drive.
87h 23h 1Bh 4h D, L 8, 13, 12 Drive comm timeout. The autoloader is
unable to communicate with the tape
drive.
87h 24h 1Bh 4h D, L 8, 13, 12 Drive comm failed. The autoloader is
unable to communicate with the tape
drive.