Operating instructions

SEPTEMBER 2005 MAGNUM 1X7 LTO AUTOLOADER
A-9
ERRORS REPORTED OVER THE SCSI BUS
3Fh 00h 13h 6h S, O 11 Operating condition changed. Over
temperature. The autoloader’s internal
temperature is at a unsafe level for the
media.
Wait until the autoloader has cooled,
then unload the cartridge to a cell and
re-load it into the tape drive.
Check the room temperature. The
ambient temperature must be no more
than 40°C (104°F).
Provide additional air flow around the
autoloader to improve cooling.
3Fh 01h 00h 6h I 10 Microcode changed. New microcode
was loaded.
3Fh 03h 00h 6h I 10 Inquiry data has changed. Data in the
Standard Inquiry Page has been altered.
Issue an INQUIRY (12h) command to
determine what the new Inquiry Data.
Compare the Standard Inquiry Data Page
to the The Original Data Page (Page
Code C0h) to determine what changed.
Note: Changes to the Standard Inquiry
data may make it necessary to
reload drivers.
3Fh 86h 15h 4h L 8, 15, 12 Checksum miscompare. The flash
EEPROM checksum was bad.
44h 00h 05h,
06h, 07h
4h T, L, D 8, 13, 12 Internal target fail. (Software error.)
Firmware consistency failure.
45h 00h 08h Bh B, L,
D, S
8, 11,
12, 13
Select/Reselect fail. A SCSI selection or
reselection failed. The host rejected the
Identify message sent by the autoloader
after the autoloader reselected the host.
47h 00h 08h Bh B, L,
D, S
8, 17,
11, 12,
13
SCSI parity error. The command was
aborted because of a SCSI bus parity error.
Table A-2 REQUEST SENSE error information (ASC, ASCQ, FSC, and SK) (continued)
ASC
(byte 12)
ASCQ
(byte 13)
FSC
Sense
Key
Cause ERP SCSI Error Message and Description