Operating instructions

SEPTEMBER 2005 MAGNUM 1X7 LTO AUTOLOADER
A-7
ERRORS REPORTED OVER THE SCSI BUS
Table A-2 REQUEST SENSE error information (ASC, ASCQ, FSC, and SK)
ASC
(byte 12)
ASCQ
(byte 13)
FSC
Sense
Key
Cause ERP SCSI Error Message and Description
00h 00h 00h 0h I 10 No error.
00h 06h 04h Bh O, B,
D, A, S
11 IO Process terminated. SCSI data
transfer aborted.
04h 01h 12h 02h O, B,
A, S
11 Logical Unit becoming ready.The
autoloader is not ready, but is in process of
becoming ready.
04h 83h 12h 02h O 11, 1 Not Ready. Door open. The cartridge
access port door is open.
04h 89h 22h 02h O 11, 2 Not Ready. Console mode. An
application tried to issue commands to
the autoloader while it was being
controlled from the Remote Management
utility.
04h 8Dh 21h 02h O 11, 2 Not Ready. Key mode. An application
tried to issue commands to the autoloader
while it was being controlled from the
operator panel.
04h 8Eh 1Eh 02h O 11, 2 Not Ready. Sequential mode. An
application tried to issue commands to
the autoloader while it was in Sequential
mode.
15h 81h 09h 4h T, L, D 8, 14,
12,13
Pick failure. The cartridge loader could
not pick a cartridge because of
mechanical problems.
15h 83h 09h 4h T, L, D 8, 14,
12,13
Put failure. The cartridge loader could not
place a cartridge because of mechanical
problems.
1Ah 00h 10h 5h A 4 Parameter length error. The parameter
list length was not valid. This error is a
result of any of the following:
Parameter List Length error in the
MODE SELECT CDB.
Illegal transfer length in CDB.
20h 00h 10h 5h A 4 Invalid Command OP code. The
operation code (OP code) for the CDB
was invalid.
21h 01h 10h 5h A, O 4 Invalid element address. There was an
invalid element address specified in the
CDB.