Operating instructions

SEPTEMBER 2005 MAGNUM 1X7 LTO AUTOLOADER
23-5
COMMAND STATUS
A parameter in the CDB or parameter list is invalid (see Table 23-1 for sense
data).
Table 23-1 Invalid parameters in the SEND VOLUME TAG CDB and parameter list
Sense
Key
ASC ASCQ
SKSV
Bit
C/D
Bit
BPV
Bit
Bit
Pointer
Field
Pointer
Error
5h 1Ah 00h 1 1 0 0 0008h Invalid Parameter List Length.
5h 21h 01h 1 1 0 0 0002h Invalid Starting Element Address.
5h 24h 00h 1 1 1
A reserved bit is set in the CDB. The
pointers point to the bit in error.
5h 24h 00h 1 1 1 3 0001h Invalid Element Type Code.
5h 24h 00h 1 1 1 4 0005h Invalid Send Action Code.
5h 26h 00h 1 0 0 0
a
Invalid reserved field in parameter list.
a
The field pointer is set to the first reserved field in the parameter list that contains a non-zero value (that is, 8, 9, 10, . . .,38, 39).