Operating instructions

22-4
SCSI REFERENCE 1012975
CHAPTER 22SEND DIAGNOSTIC (1Dh)
22.3.1 SUPPORTED DIAGNOSTIC PAGES PAGE (PAGE CODE 00h)
When the value of the Page Code field (byte 00) in the Diagnostic Parameter
Header is 00h, the data that follows contains parameters for the Supported
Diagnostic Pages page. This page allows the initiator to retrieve the list of
supported pages using the RECEIVE DIAGNOSTIC RESULTS command. The
value in the Page Length field (bytes 2 and 3) of the Diagnostic Parameter
Header for this page is 0000h, indicating that there are no parameters
associated with this diagnostic page.
22.3.2 SELF TEST PAGE (PAGE CODE F0h)
When the value of the Page Code field (byte 00) in the Diagnostic Parameter
Header is F0h, the Self Test page is executed by the SEND DIAGNOSTIC
command. The value in the Page Length field (bytes 2 and 3) of the Diagnostic
Parameter Header is 0000h, indicating that there are no parameters associated
with this diagnostic page. This diagnostic page has the same effect as setting
the SelfTest bit (byte 1, bit 2) in the CDB.
Bit
Byte
7 6 5 4 3 2 1 0
00 Page Code (00h)
01 Reserved
02 (MSB)
Page Length (0000h)
(LSB)
03
Bit
Byte
7 6 5 4 3 2 1 0
00 Page Code (F0h)
01 Reserved
02 (MSB)
Page Length (0000h)
(LSB)
03