Operating instructions

SEPTEMBER 2005 MAGNUM 1X7 LTO AUTOLOADER
22-1
22
SEND DIAGNOSTIC (1Dh)
22.1 ABOUT THIS COMMAND
The SEND DIAGNOSTIC command causes the autoloader to perform its
diagnostic self-test. If a test is successful, the autoloader returns Good status;
otherwise, it returns Check Condition status. When this command is followed
by a RECEIVE DIAGNOSTIC RESULTS (1Ch) command or a REQUEST
SENSE (03h) command, the results of the self-test are reported to the initiator.
Notes:
To ensure that the diagnostic data returned is valid, the SEND DIAGNOSTIC
command must be immediately followed by the RECEIVE DIAGNOSTIC
RESULTS command.
To ensure that the results of the diagnostic test are not destroyed by a command
sent by another initiator, the autoloader should be reserved for the initiator’s
exclusive use.
The initiator must support the disconnect option if you plan to use the SEND
DIAGNOSTIC command because the autoloader will disconnect from the
initiator while the command is executing.
Bit
Byte
7 6 5 4 3 2 1 0
00 00011101
01 Reserved PF RSVD SelfTest DevOfl UnitOfl
02 Reserved
03
Parameter List Length
04
05 00 Reserved 00