Operating instructions

19-14
SCSI REFERENCE 1012975
CHAPTER 19—REQUEST VOLUME ELEMENT ADDRESS (B5h)
19.3.7 ASC AND ASCQ VALUES FOR ABNORMAL STATES
Table 19-2 contains a list of the ASC and ASCQ values that appear in the
Additional Sense Code and Additional Sense Code Qualifier fields of an
element descriptor if the element is in an abnormal state. Table 19-2 also
indicates the corrective action for each abnormal state. The Except field of an
element descriptor indicates if the element is in an abnormal state.
Table 19-2 ASC and ASCQ values for abnormal element conditions
ASC ASCQ Description Corrective Action
83h 00h Label questionable
The bar code label is questionable. Issue an INITIALIZE
ELEMENT STATUS (07h or E7h) command to reread the
label.
Replace the label. Refer to the Magnum 1x7 LTO Autoloader
Product Manual for information about placing the labels on
the cartridges.For specifications for the bar code labels that
can be used with the autoloader, refer to the Exabyte Bar
Code Specification for LTO Ultrium Cartridges.
If the error persists, contact your service provider.
83h 01h Cannot read bar
code label
Replace the label. Refer to the Magnum 1x7 LTO Autoloader
Product Manual for information about placing the labels on
the cartridges.For specifications for the bar code labels that
can be used with the autoloader, refer to the Exabyte Bar
Code Specification for LTO Ultrium Cartridges.
If the error persists and the label is properly placed, contact
your service provider.
83h 03h Label and full status
questionable
The autoloader was powered on or the cartridge access port
door was opened. The cartridge inventory may have been
violated. Issue an INITIALIZE ELEMENT STATUS (07h or E7h)
command to reestablish the cartridge inventory.
83h 09h No bar code label
If the cartridge does not have a bar code label, place a label
on the cartridge. Refer to the Magnum 1x7 LTO Autoloader
Product Manual for information about placing the labels on
the cartridges.For specifications for the bar code labels that
can be used with the autoloader, refer to the Exabyte Bar
Code Specification for LTO Ultrium Cartridges.
If error persists and a label is present and properly placed,
contact your service provider.