Operating instructions
SEPTEMBER 2005 MAGNUM 1X7 LTO AUTOLOADER
18-3
WHAT THE AUTOLOADER RETURNS
18.3 WHAT THE AUTOLOADER RETURNS
The autoloader returns the standard extended sense bytes, as described below.
Sense Key – Byte 02, Bits 3 through 0
Table 18-1 contains descriptions of the sense key values supported by the
autoloader.
Bit
Byte
7 6 5 4 3 2 1 0
00 RSVD1110000
01 00h
02 000RSVD Sense Key
03 (MSB)
Information Bytes
(LSB)
...
06
07 Additional Sense Length
08 (MSB)
Command Specific Information
(LSB)
...
11
12 Additional Sense Code (ASC)
13 Additional Sense Code Qualifier (ASCQ)
14 Field Replaceable Unit Code
15 SKSV (MSB)
Sense Key Specific
(LSB)
16
17
18 Fault Symptom Code (FSC)
19 FSC Command
Table 18-1 Sense key descriptions
Hex Value Sense Key Description
0h No Sense Indicates that there is no specific sense key information to be reported
for the autoloader.
2h Not Ready Indicates that the autoloader is not ready to perform cartridge loader
motion commands.