Operating instructions
SEPTEMBER 2005 MAGNUM 1X7 LTO AUTOLOADER
15-5
WHAT THE AUTOLOADER RETURNS
15.3.2 ELEMENT STATUS PAGE
The autoloader returns one Element Status page for each group of element
descriptors of the same type (that is, it returns one page for each of the
following: cartridge loader, cartridge storage locations, and tape drive). The
Element Status page is returned only if there is at least one Element Descriptor
also being returned.
Element Type Code – Byte 00
This field indicates the specific element type (see page 15-2) being reported by
the element descriptor.
PVolTag – Byte 01, Bit 7
This field indicates if primary volume tag (bar code label) information is
present, as follows:
0 – Volume tag bytes are omitted from the element descriptors
1 – Volume tag information is present
AVolTag – Byte 01, Bit 6
The autoloader does not support alternate volume tags. The value reported for
this field is 0.
Element Descriptor Length – Bytes 02 and 03
This field indicates the total number of bytes contained in a single element
descriptor, as follows:
If the descriptor being returned is for either the medium transport element
(the cartridge loader) or a storage element (cartridge cell), the length is either
52 bytes (if the VolTag bit is 1) or 16 bytes (if the VolTag bit is 0).
Bit
Byte
7 6 5 4 3 2 1 0
00 Element Type Code
01 PVolTag AVolTag Reserved
02 (MSB)
Element Descriptor Length
(LSB)
03
04 Reserved
05 (MSB)
Byte Count of Descriptor Data Available
(LSB)
06
07