Operating instructions

10-16
SCSI REFERENCE 1012975
CHAPTER 10—MODE SENSE (1Ah)
Cleaning Cartridge Storage Element – Byte 3
This field indicates the element address of the storage element that is reserved
for a cleaning cartridge. This field is only valid when the FixEnbl bit is 1.
10.3.8 OPERATING MODE PAGE (PAGE CODE 26h)
The Operating Mode page indicates the current operating mode for the
autoloader. For more information about operating modes, refer to the
Magnum 1x7 LTO Autoloader Product Manual.
PS (Page Savable) – Byte 00, Bit 7
The value returned for this field is 0, which indicates that the autoloader
cannot save this page to nonvolatile memory.
Page Code – Byte 00, Bits 5 through 0
This field identifies the Clean Configuration page. The value of this field must
be 26h.
Parameter Length – Byte 01
This field indicates the length, in bytes, of the Operating Mode page. The valid
value for this field is 02h (2), which indicates that 2 bytes of data follow this
byte.
OperMode – Byte 02, Bit 0 - Bit 1
This bit indicates the current operating mode for the autoloader, as follows:
0h – Random mode
1h – Sequential mode
2h – Manual mode (the autoloader is controlled from the operator panel)
3h – Ethernet mode (the autoloader is controlled through the Remote
Management utility)
Refer to the Magnum 1x7 LTO Autoloader Product Manual for information about
Random and Sequential modes.
Bit
Byte
7 6 5 4 3 2 1 0
00 PS RSVD Page Code (26h)
01 Page Length (02h)
02 Reserved OperMode
03 Reserved