Operating instructions

10-14
SCSI REFERENCE 1012975
CHAPTER 10—MODE SENSE (1Ah)
Write Line 1 – Byte 02, Bit 3
This field indicates the type of text that appears on Display Line 1 of the LCD
Status Screen (bytes 04 through 19 of the LCD Mode page), as follows:
0 Autoloader default text.
1 Text you specified in bytes 04 through 19 of the MODE SELECT LCD Mode
page.
The factory default is 0. You can change this field with the MODE SELECT
command (see page 9-10).
Note: The text specified for Display Line 1 is displayed when the autoloader
does not have any active status to display (that is, the cartridge loader is
ready to receive commands and there are no error conditions).
Display Line 1 – Bytes 04 through 19
This field indicates the text that will appear on line 1 of the LCD. Display
Line 1 is typically used to specify the product name displayed on the LCD.
The default product name for the autoloader is “LTO 1x7 2U”. You can change
this field with the MODE SELECT command (see page 9-10).
10.3.7 CLEANING CONFIGURATION PAGE (PAGE CODE 25h)
The Cleaning Configuration page indicates how the autoloader behaves when
it is configured to autoclean the tape drive.
Page Code – Byte 00, Bits 5 through 0
This field identifies the Clean Configuration page. The value of this field must
be 25h.
Parameter Length – Byte 01
This field indicates the length, in bytes, of the Cleaning Configuration page.
The valid value for this field is 02h (2), which indicates that 2 bytes of data
follow this byte.
Bit
Byte
7 6 5 4 3 2 1 0
00 Reserved Page Code (25h)
01 Page Length (02h)
02 Reserved Auto FixEnable
03 Cleaning Cartridge Storage Element