Operating instructions

10-8
SCSI REFERENCE 1012975
CHAPTER 10—MODE SENSE (1Ah)
ST (Storage Element) – Byte 02, Bit 1
The value returned for this field is 1, which indicates that the cartridge storage
locations can store cartridges.
MT (Media Transport) – Byte 02, Bit 0
The value returned for this field is 0, which indicates that the cartridge loader
cannot store cartridges.
MT DT – Byte 04, Bit 3
The value returned for this field is 0, which indicates that the autoloader does
not support the MOVE MEDIUM (A5h) command when the source is the
cartridge loader and the destination is the tape drive.
MT I/E – Byte 04, Bit 2
The value returned for this field is 0, which indicates that the autoloader does
not support the MOVE MEDIUM (A5h) command when the source is the
cartridge loader and the destination is the entry/exit port element.
MT ST – Byte 04, Bit 1
The value returned for this field is 0, which indicates that the autoloader does
not support the MOVE MEDIUM (A5h) command when the source is the
cartridge loader and the destination is a cartridge storage location.
MT MT – Byte 04, Bit 0
The value returned for this field is 0, which indicates that the autoloader does
not support the MOVE MEDIUM (A5h) command when the source is the
cartridge loader and the destination is the cartridge loader.
ST DT – Byte 05, Bit 3
The value returned for this field is 1, which indicates that the autoloader
supports the MOVE MEDIUM (A5h) command when the source is a cartridge
storage location and the destination is a tape drive.
ST I/E – Byte 05, Bit 2
The value returned for this field is 0, which indicates that the autoloader does
not support the MOVE MEDIUM (A5h) command when the source is a
cartridge storage location and the destination is the import/export element.
ST ST – Byte 05, Bit 1
The value returned for this field is 0, which indicates that the autoloader does
not support the MOVE MEDIUM (A5h) command when the source is a
cartridge storage location and the destination is a cartridge storage location.
ST MT – Byte 05, Bit 0
The value returned for this field is 0, which indicates that the autoloader does
not support the MOVE MEDIUM (A5h) command when the source is a
cartridge storage location and the destination is the cartridge loader.