User Guide

Table Of Contents
EWC Controls Inc. 385 Highway 33 Englishtown, NJ 07726 800-446-3110 FAX 732-446-5362 E-Mail- info@ewccontrols.com
2
UZC4
MAIN
CONTROL
PANEL
ZONES 1-4
O
N
12 34
CTS 206-4
ZXM2
ZONES 5-6
O
N
12 34
CTS 206-4
ZXM2
ZONES 7-8
FIELD BUS CABLE ROUTING
UZC4
MAIN
CONTROL
PANEL
ZONES 1-4
O
N
12 34
CTS 206-4
ZXM2
ZONES 5-6
UZC4
MAIN
CONTROL
PANEL
ZONES 1-4
O
N
12 34
CTS 206-4
ZXM2
ZONES 5-6
O
N
12 34
CTS 206-4
ZXM2
ZONES 7-8
O
N
12 34
CTS 206-4
ZXM2
ZONES 9-10
UZC6 UZC8
UZC10
TO PASS THE BUS CABLE THROUGH THE KNOCK
OUTS OF THE HOUSING, FOLD THE 10-PIN HEADER
AGAINST THE CABLE SO IT WILL FIT EASILY.
FIELD BUS CABLES ARE ROUGHLY 40” IN
LENGTH, SECURE CABLE AS NECESSARY.
KNOCK-OUT ON HOUSING
All Expansion module Dip switch banks must be set
correctly for proper zone address identification. The
1st expansion module would be zones 5 & 6. The
2nd expansion module would be zones 7 & 8. The
3rd expansion module would be zones 9 & 10. And
so on up the line for a total of 22 zones.
The switches are set for you at the factory unless
you are expanding the system in the field. It is a
good idea to check them anyway.
DO NOT CONNECT OR DISCONNECT BUS CABLES WHILE POWER IS APPLIED TO THE
SYSTEM. DOING SO MAY DAMAGE THE ZXM2 MODULES AND VOIDS ALL WARRANTIES.
NOTE:
THE ZXM-2 PACKAGE CONTAINS AN
EXPANSION HEADER AND A 3-
CONNECTOR CABLE (ITEMS NOT
SHOWN). THESE ITEMS ARE ONLY
REQUIRED IF YOU ARE EXPANDING
A UZC6 TO A UZC8, CONTACT TECH.
SUPPORT FOR DETAILS.