The following screenshot presents page 4 of the Operation tab in the server-based
application, where the EVS Controller settings are available:
Effect duration for take
Description Defines the duration of the transition when using the TAKE
key to chain 2 sequences in PGM+PRV mode.
Values Range of values: 00s00fr to 20s00fr.
Default value 00s05fr
Fast jog
Description Sets the increment of the jump when the Remote Panel is
used in Fast Jog mode.
Values The values from 1 to 20 times are possible.
Default value 20x