Configuration Manual Owner manual

Rules for Controller Assignment
Main Rules for XT2 server
On an XT2 server, the following main rules are applicable:
In a Multicam LSM base configuration:
All Remote Panels must be the first in the list of main controllers, without gap. It is
not allowed to have another controller preceding a Remote Panel in this list.
Other controllers can be assigned as secondary controllers to PGMs taking into
account the protocol-specific rules.
No more than 4 play channels on an EVS server can be assigned to Remote
Panels, and no more than 3 play channels can be assigned to one Remote Panel.
Only a Remote Panel (no other controller) can be assigned to a REC channel as a
main controller.
No secondary controller can be assigned to a REC channel.
In a Spotbox or Server base configuration:
A Remote Panel is not allowed.
Controllers other than the EVS Remote can be assigned to play or record
channels, taking into account the protocol-specific rules on controller use and
combinations.
XT2 Server- Version 11.01- Configuration Manual
3. Multicam Configuration 96