Electrical Specifications
Rated voltage: 115 to 240 VAC (single phase)
Rated frequency: 47-63 Hz
Input connector: CEE 22/IEC 320 3-pin male receptacle
Connection to supply: Pluggable equipment Type A (EN60950 §1.2.5): Equipment which
is intended for connection to the building power supply wiring via a non-industrial plug and
socket-outlet or a non-industrial appliance coupler or both. Correct mains polarity must
always be observed. Do not use reversible power plugs with this equipment.
Class of equipment: Class 1 equipment (EN60950 § 1.2.5): electric shock protection by
basic insulation and protective earth.
Electrical Consumption
The following electrical specifications are valid for the XT3 6U server:
Data Type Voltage Value
Inrush current (PSU plugged on power grid) 230 V 3.8 A
Maximal current (full load, CPU at 100% ) 230 V 1.7 A
Inrush current (PSU plugged on power grid) 110 V 7.9 A
Maximal current (full load, CPU at 100% ) 110 V 3.6 A
Maximal power consumption (full load, CPU at 100%) - 400 W
3.3. Environmental Conditions
Operating
Temperature: 10°C to + 5C (50°F to 122°F) ambient with free air flow
Relative humidity: 0% to 90% (non-condensing)
Cooling requirements: Forced air cooling air flow from front to back
Handling/movement: Designed for fixed use when in operation
Storage and Transport
Temperature: C to +70°C (32°F to 15F)
Relative humidity: 0% to 90% (non-condensing)