User's Manual User guide

IP Director Version 4.3 – User Manual – Part 3: Ingest and Play-Out
EVS Broadcast Equipment
Issue 4.3.C
175
When On GPI is selected, the corresponding GPI, which has
been configured to start a PLAY command on the on-air
channel associated to the play-list tab, is displayed in the
description field.
On Time, at: the element will start at the defined time. The
element will only be started if the element is on-air at the
specified time (independently of the date).
The element will start playing using the parameters defined in
the play-list relating to the element.
Note
If the Automatically option was selected when a start
mode is defined (Manually, on GPI, On Time, at), the
still mode will default to the ‘stop on Last frame of
previous clip’ mode.
6.9.4 PLAY-LIST PREDEFINED VALUES SETTINGS
PREDEFINED EFFECT DURATION
This allows the pre-selection of three default values that can be
used when defining a custom effect value for an element in a
play-list.
These values are proposed in the combo box in the “define A/V
duration” for the transition, when on the Play-List Editor panel.
PREDEFINED AUDIO SWAP CONFIGURATION
This setting allows the user to set up common audio swap
configurations in advance to facilitate an efficient way of
changing configurations when building play-lists.
Common configurations can be made, named and added to a list
using this set-up area.
Once configurations have been defined they can be selected for
use using the Insert/Edit Tag command from the Play-List Editor
contextual menu. For more information on the use of Tags, see
section ‘Insert Tag’, on page 146.