T-100-R Operation Guide
Table of Contents Page 2 Overview Main Thermostat Screen Setting the Heating or Cooling Temperature Setpoint Setting the System Mode: Off, Heat, Cool, Auto Setting the Fan Mode and System Status Indicators 3 4 5 6 Menu Selection Main Menu Items 7 Menu Options 8 User Settings Menu Items 9-10 Away Setpoints, Z-Wave Install & Thermostat Info 11 Thermostat Operation 12 Z-Wave Installation General Programming Procedure & Setback Mode Operation 13 FCC/IC Information to User 14
Operation Guide Page 3 Main Thermostat Screen Backlight Display Room Temperature Setpoints Temperature Setting 4:30 PM SYS OFF ECON HOLD NO MSG MENU 74 COOL MODE AUTO FAN 72 H 75 C HOLD Warmer Cooler Run/Hold Menu Mode Selection Selection Heating/Cooling Fan Mode Mode Selection Selection Minimized Display 75 Press any button to return to the main thermostat screen
Operation Guide Page 4 Setting the Heating or Cooling Temperature Setpoint 4:30 Sys Off MENU 64H 75 HEAT MODE AUTO FAN 82C Press a button to go to the setpoint change screen HOLD Press the up or down arrow buttons to set the desired temperature setpoint Setpoint change screen HEATING SETPOINT 64 70 DONE Done Press “DONE” button to set the setpoint and exit back to the main thermostat screen or wait for the screen to automatically time out.
Operation Guide Page 5 Setting the System Mode: Off, Heat, Cool, Auto 4:30 PM Sys Off MENU 75 HEAT MODE AUTO FAN 64H 82C HOLD Press Mode button to change system mode System Mode change screen SYSTEM MODE OFF HEATING COOLING AUTO Done MODE Press the UP or DOWN buttons or MODE button to select the desired system mode Press “DONE” button to select the mode and exit back to the main thermostat screen or wait to automatically time out. System Modes • OFF: System is off.
Operation Guide Page 6 Setting Fan Mode and System Status Indicators System Status Indicators 4:30 PM Sys Off 2nd Stg Filter MENU 75 HEAT MODE AUTO FAN 64H 82C HOLD Press the Fan button to change the Fan mode. • • AUTO FAN: Fan automatically operated by the HVAC system. FAN ON: Manual Fan mode. Fan stays on until mode is changed back to Auto. Operational Fan Mode Fan Cycler.
Operation Guide Page 7 Menu Selection 4:30 PM Sys Off MENU 75 HEAT MODE AUTO FAN 64H 82C HOLD Press Menu button to go to the main menu screen Menu Selection Energy Usage Utility Setup Messages Schedules Done Press DONE to go back to the main thermostat screen Select Use the UP/DOWN buttons to select the desired menu item Press SELECT to go to the menu item screen Main Menu Items • Energy Usage Enabled for In-Home Display versions • Utility Setup Enabled for In-Home Display versions • Messa
Operation Guide Page 8 ...as per that days schedule stored in the thermostat. “Hold” mode stops schedule operation and holds the current setpoints until changed manually or by network commands. The Schedules Screen gives you the option of setting a custom setback schedule or to load one of two preset schedules. Menu Options • Heat and Cool: You can change the individual day/hour and setpoints for the Heating and Cooling schedule by selecting this menu item.
Operation Guide User Settings Menu Items • Set Clock go to the clock setting screen • Filter Service go to the filter timer setup screen • Maint Service go to the maintenance timer setup screen • Screen Timeout sets the time in seconds to switch to the minimized screen • F/C Settings go to the F/C mode selection screen • Sensor Calibration go to the sensor calibration screen • Backlight/Display go to the backlight and display setup screen Page 9 Select Schedule Done Select Set Clock The
Operation Guide Page 10 Screen Timeout Minimized Screen. Set the display timeout time in seconds. Options are 0 or 15 to 120 (default set to 0 seconds). This is the time before the main thermostat screen reverts to the minimized temperature only display screen, after the last button press. The Minimized Screen feature is disabled by setting this time to “0”. Any button press will restore the main thermostat screen display. F/C Settings Go to the F/C Settings Screen.
Operation Guide Page 11 Away Setpoints Away setpoints are used when the thermostat is set to the setback or away mode. Away Setpoints Away – Heat Away – Cool Done + Press DONE to store the setting and exit back to the main menu Use up/down buttons to select setpoint to change 65 80 - Set Use +/- buttons to increase or decrease the temperature Z-Wave Install This menu item allows you to install or uninstall the thermostat into the Z-Wave network.
Operation Guide Thermostat Operation Minimum Run Time (MRT) The thermostat has a Minimum Run Time after the start of any heating or cooling call. This minimum run time assures even heating and cooling cycles. The MRT delay will keep the system on even if reaches setpoint or you change the setpoint to a temperature that would satisfy the call, until the MRT expires. Changing the Mode to OFF will cancel the MRT and the system will turn off immediately.
Operation Guide Page 13 Z-Wave Installation Z-Wave controllers from various manufacturers may support the Z-Wave Thermostat General V2 Device class used by the Z-WAVE Thermostat. The following procedure will allow the thermostat to be added to a Z-Wave network. General Programming Procedure (for controllers supporting the thermostat device class): 1.
Operation Guide Page 14 FCC/IC INFORMATION TO USER This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for Class B Digital Device, pursuant to Part 15 of the FCC Rules.