Third Party Verification Claim

Table 1
ASTM E330 Standard Test Method for Structural Performance of Exterior Windows,
Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference Test Results
Support Spacing Sample No. Ultimate Load (PSF) 15% Tolerance
16-inch OC 1 -385.73 PASS
16-inch OC 2 -418.49 PASS
16-inch OC 3 -386.83 PASS
-397.02
-132.34
-104.15
24-inch OC 1 -219.86 FAIL
24-inch OC 2 -308.03 PASS
24-inch OC 3 -284.61 PASS
-270.83
-90.28
-71.05
Average
Average
Notes:
1
The values are based on testing per ASTM E330, and
represent the capacity of the sample to resist flexure or fastener pull-
through using a 3.0 safety factor.
2
The values are reduced proportionately based on AC92 Section 4.2.2
Conditions of Acceptance.
Reduced Allowable Load (PSF)
2
Reduced Allowable Load (PSF)
2
Allowable Load (PSF)
1
Allowable Load (PSF)
1