Third Party Verification Claim
Table Of Contents
HOME INNOVATION
Report No: RJ5020P-1
January 18, 2017
Page 2 of 3
THIS REPORT IS THE CONFIDENTIAL PROPERTY OF THE CLIENT ADDRESSED. THE REPORT MAY ONLY BE REPRODUCED IN FULL. PUBLICATION OF EXTRACTS FROM THIS REPORT IS
NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM QAI. ANY LIABILITY ATTACHED THERETO IS LIMITED TO THE FEE CHARGED FOR THE INDIVIDUAL PROJECT FILE REFERENCED.
THE RESULTS OF THIS REPORT PERTAIN ONLY TO THE SPECIFIC SAMPLE(S) EVALUATED.
WWW.QAI.ORG
info@qai.org
SALT SPRAY (FOG) EXPOSURE TEST PER ASTM B117
Test Procedure
Testing was performed was in accordance with ASTM B117-16, Standard Practice for Operating Salt Spray
(Fog) Apparatus. Three, 4-inch by 6-inch specimens were placed in a salt spray (fog) chamber and subjected
to a total of 300 hours of salt spray exposure with visual examinations made every 100 hours.
The salt spray (fog) chamber was calibrated in accordance with ASTM B117-16.
Test Results
Specimen No.
Observations
1
No cracking, checking, crazing, erosion, delamination or other deleterious effects were
observed after 100, 200 and 300 hours of exposure.
2
No cracking, checking, crazing, erosion, delamination or other deleterious effects were
observed after 100, 200 and 300 hours of exposure.
3
No cracking, checking, crazing, erosion, delamination or other deleterious effects were
observed after 100, 200 and 300 hours of exposure.