6. FOOTPLATE ANGLE ADJUSTMENT
Note: The footplate is factory set and adjusted so that the blade
cuts at 90
0
to the footplate.
The footplate may be tilted to an angle of up to 45
0
to either side with
positive location stops at 15
0
, 30
0
and 45
0
.
To adjust the footplate:
WARNING: Disconnect the jigsaw from the power supply before
attempting to adjust the footplate.
Unclip the plastic footplate shoe and store safely for future
installation. (Fig. 6)
Withdraw the Dust Extraction Adaptor tube, if tted, and store
safely for future installation. (Fig. 7)
Loosen the socket headed screw that holds the footplate to the
machine. (Fig. 8)
Tilt the footplate to the desired angle. To engage one of the
positive stops it will be necessary to slide the footplate backwards
or forwards depending upon the stop required.
Tighten the socket-headed screw carefully so as not to damage
the threads.
Re-install the Dust Extraction Adaptor tube.
Refit the plastic footplate shoe ensuring that all six (6)
securing lugs (2 to the front of the footplate and 2 either side)
are correctly seated.
Note: The positive location stops are intended as a guide only. For
accurate setting of the footplate we recommend the use of a vernier
angle gauge (not supplied).
Fig 6
View of footplate shoe being
unclipped and removed from
footplate.
Fig 7
View of Adaptor tube in service
position.
Fig 8
Close up view of socket headed
screw.