Use and Care Manual

9
www.evolutionpowertools.com
EN
DE
FR
CHECKING and ADJUSTING THE SAW MOUNTING
BRACKET CLAMPING PRESSURE
The pressure exerted by the clamping mechanism within a saw
mounting bracket can be adjusted. The clamping pressure of
each bracket should be checked before it is attached
to a mitre saw.
When tted across the mitre saw stands two main crossbars,
and with the locking handle in the down (locked) position,
a bracket should be rm and exhibit no signs movement.
Excessive force to deploy the locking lever to the down
position should be avoided. Gently pressing the lever
downwards with the palm of a hand should be all the force
needed to operate the locking lever.
To adjust the clamping pressure:
• Turntheclampupsidedowntorevealthemechanism.
• Loosenthelockingnut.(Fig. 5)
• Turntheadjustmentscrew(Fig. 6) clockwise to increase
the clamping pressure. Turn the screw counter-clockwise to
decrease the clamping pressure.
• Tightenthelocknutwhenadjustmentissuccessfully
completed.
Fig. 6
Fig. 5