Specifications

CHAPTER 1
6
INSTALLATION
Before installation it is very important to ensure 4 variables
are carefully checked to allow the unit to operate correctly
1. Adequate Air Flow
2. Correct water ow volume
3. Correct electrical connection & supply
4. Heater condition
1. Air Flow
Installing the heater indoors or in an enclosed space will result in very poor performance and
can in extreme cases damage the heater. Ensure the heater is installed in a well ventilated
area with plenty of fresh air, a minimum gap between walls/fences etc of 600mm on the
sides and 1500mm overhead clearance.
Important: Ensure that the cold air off the top of the heater does not recycle through
the heater.
SEE PAGE 8 FOR FURTHER INFORMATION
2. Water Flow
It is CRITICAL that there is sufcient water ow to the unit. Incorrect waterow can cause a
loss of efciency and possible damage to the unit. Optimal water ow rates are listed in the
Evoheat sales brochure and in this manual on page __. It is imperative that water ow is kept
as close as possible to these ow rates. Correct water ow not only offers optimal heater
performance, but may also prevent possible damage to your heater.
SEE PAGE 9 FOR FURTHER INFORMATION
3. Electrical Connection
Always use a qualied Electrician to perform any electrical work. Ensure the power cable and
circuit breaker are of a suitable size for the heater being installed. Also check that there is
adequate voltage and current available at the heater connection to run the unit. Voltage range
should be 220-240 volts for single phase, and 380-415 volts for 3 phase units. Voltage ranges
outside these parameters will cause heater damage and void your warranty. Correct phase
connection is important with 3 phase heaters.
SEE PAGE 10 FOR FURTHER INFORMATION