3.7 Water Pump Connection
There are 2 methods to install an Evo heat pump.
1. EXISTING FILTER PUMP/CHLORINATOR/TIMER CONTROLS THE HEATER
4 Integrated Operation Ideal mode for retro t to existinglter/pump set ups. Operation
of the lter pump controls the heater start and shut down timing.
2. HEATER CONTROLS A DEDICATED WATER PUMP
This option is required for Programmed Options modes. This water pump is installed
for heater circulation only.
This method requires the water pump to be hard-wired into the heater via the Pump
Power inlet. With the water pump wired in this manner the heater is able to operate in
the following mode.
4 Programmed Options Allows you to select the daily start and stop time of both the
heater and water pump. This mode can also be used as Set and Forget auto mode.
3.8a Initial start up at handover
METHOD 1 - WATER PUMP CONTROLS THE HEAT PUMP
(For operating instructions refer to Chapter 2)
a. Check the connections, wires and cables of the unit are correctly installed.
b. Turn on the water pump. Check for water leakage and check for optimum water ow.
Adjust water ow by adjusting bypass valves until water ow through heater is sufcient.
c. Turn on the power to the heater at the main isolating switch. With the heater in STAND-
BY mode, enter the MAIN MODE SELECT menu and select HEAT. ESC back to the rst
menu screen and select the PARAMETER menu and adjust the HEAT TEMP to 30 de-
grees (adjust higher if the pool water temp is hotter than 30 degrees)