Figure 2
5
www.evil-paintball.com
Normal Mode Configuration Mode
GREEN - TRIGGER SENSITIVITY. VALUES 1-20 (factory default 5)
Trigger sensitivity is the amount of time that the trigger has to be released before the next
trigger pull is allowed. In some situations with too low of a value, the marker may begin to
shoot full-auto.
RED - DWELL. VALUES 1-40 (factory default 18)
Dwell is the amount of time that the solenoid will be activated. Follow these steps for the best
way to set your dwell:
• Remove loader and any paintballs from the EVIL
®
MINION
™
.
• With the dwell set at 15, start increasing the value until the EVIL
®
MINION
™
begins to fire.
• When you reach the setting where the EVIL
®
MINION
™
begins to fire, get some paint and a
loader and go to a chronograph.
• Increase the dwell until you see no increase in the velocity. This is the optimal dwell setting
to be used.
ORANGE - RATE OF FIRE (VALUES 1-20)
The ROF setting is used to set the maximum rate of fire of the EVIL
®
MINION
™
. The values do
not correspond directly to a certain Balls Per Second (BPS) value. You will need to use the table
below to locate your desired maximum ROF setting. The factory default is 15 (20 BPS). This
setting is used both when the Eye function is turned on and off.
1 10 BPS
2 11 BPS
3 12 BPS
4 13 BPS
5 14 BPS
6 14.5 BPS
7 14.7 BPS
8 14.9 BPS
9 15.2 BPS
10 15.4 BPS
11 15.6 BPS
12 15.9 BPS
13 16 BPS
14 18 BPS
15 20 BPS
16 22 BPS
17 24 BPS
18 26 BPS
19 28 BPS
20 30 BPS
FLICKERING ORANGE - FIRE MODE (VALUES 1-3)
The fire mode setting is used to select the fire mode of the EVIL
®
MINION
™
. Factory default is
semi-automatic mode; one trigger pull shoots out one paintball. The Millennium mode and
the PSP mode follow the rules of the paintball tournament series.
Value 1 - Semi automatic mode
Value 2 - PSP Mode
Value 3 - Millennium Mode
TO CHANGE A VALUE OF A SETTING
1. While in the configuration mode choose the color you wish to change by pulling the trigger.
2. When the LED indicates the color you wish to change, pull and hold the trigger until the
LED starts to flash.
3. The LED will flash as many times as the previous setting was and it will then turn off. Now
pull the trigger as many times as you wish the new setting to be.
4. When done, the LED will cycle through all the colors again to indicate setting was saved and
turn back to Green. You can now change another setting or quit the configuration mode.
5. To exit the configuration mode, set DIP 2 to the off position.