User's Manual

14
www.evil-paintball.com
EVIL
®
MINION
TROUBLE SHOOTING GUIDE
AIRLEAKS
AIR LEAKING FROM THE EVIL
®
MINION
AIRPORT
Check the O-ring on the Air system. If needed install a new O-ring and
try again. The O-ring normally used is #15 but some manufacturers might
use a different size. Consult the manual of the air system you are using.
Check that the hose connector is tight. Remove the hose from the
connector by pushing the gray plastic towards the connector and pull out
hose. If needed remove and apply thread sealant to the thread and
re-tighten. If unsure consult expert advice.
Check that the end of the hose is cut straight and is not worn out. If
needed cut a small piece off the hose with a razor blade and re-insert
hose into the fitting. Make sure hose goes all the way to the end.
AIR LEAKING FROM THE EVIL
®
MINION
HYPER2
REGULATOR
First locate the position of the leak
For disassembly instructions consult the technical section under Hyper2
regulator.
If the leak is coming from the bottom of the regulator you will need to
dis-assemble the regulator and change the #010 O-ring and the seat on
the brass seat retainer mounted inside the Hyper2
regulator.
If the leak is coming from the swivel piece where the hose connector
mounts you will need to change the two #013 O-rings under the swivel
piece or tighten the hose connector.
If the leak comes from the small hole in the middle of the regulator there
are two possible O-rings. Change the #020 o-ring on the piston and the
#007 urethane O-ring inside the body of the regulator
If the leak is from the top of the regulator change the #015 O-ring on
the outside of the cap.
AIR LEAKING FROM THE ASA
Next change the #015 O-ring on the top cap of the Hyper2
and apply a
small amount of lube to the O-ring
AIR LEAKING BETWEEN BODY AND FRAME
Leak between the body and the frame can be caused by a couple of
things.
First pull out the bolt kit and change the #015 sail O-ring and the three
#020 O-rings on the outside of the can.
If above doesn’t help remove the frame from the EVIL
®
MINION
and
remove the solenoid by unscrewing the two screws mounting it down.
Apply some lube to the seat underneath the solenoid and re-assemble
making sure that the solenoid is well tightened into the body and that
the eye wire is not pinched underneath the solenoid.
Last possibility is that one of the gas passages is leaking. Gas up the
EVIL
®
MINION
without the frame attached and try to locate the exact
point of leakage. If leak is coming from one of the blocked holes remove
the screw, apply some thread sealant and re-attach screw to the body.
AIR LEAKING FROM BACK OF THE EVIL
®
MINION
Check that the bolt kit is tightened all the way into the EVIL
®
MINION
.
If the bolt kit is loose, it will start to leak.
If above does not solve the leak, remove the bolt kit and change the
#020 O-ring on the back part of the bolt. Also change the two #009
O-rings located in the stem of the bolt. Lube well and re-insert the bolt
kit into the EVIL
®
MINION
. Check bolt kit break down picture on page 9
for O-ring locations.
Last check that the gas passage blocking screw located on the right side
of the EVIL
®
MINION
is not leaking. If the leak is coming from this hole
remove screw and apply thread sealant to it. Make sure to tighten screw
well and wait for sealant to dry before re-gassing marker.
AIR LEAKING FROM FRONT OF THE EVIL
®
MINION
Remove the bolt kit from the marker and change the #017 O-ring located
inside of the can and the #014 O-ring located inside the manifold.
Lube well and re-assemble.
• If above doesn’t help try changing the #020 O-rings located outside of the
can. Lube well before re-inserting bolt kit.
PROBLEMS WITH ELECTRONICS
EVIL
®
MINION
WON’T TURN ON
Make sure battery is new
Check that battery is connected to the 9V clip inside the EVIL
®
MINION
and that the other end of the 9V harness is connected to the board
Make sure there is no dirt or debris blocking the button from being
pressed
EVIL
®
MINION
WILL TURN ON/OFF BY ITSELF OR THE EYES WILL TURN
ON/OFF BY THEM SELVES
Both of these problems are caused because the button(s) are pressed all
the time.
Remove board from the frame by removing the grip panel on the left
hand side, disconnecting the cables and pulling the board out.
Carefully remove the two buttons and clean them well.
Re-assemble and test. If problems persist, contact authorized service
center for board replacement.
EYES WILL NOT WORK, LED KEEPS BLINKING GREEN
First change the battery. The eyes are normally the first thing to stop
working when a battery is dying.
Next try to clean the eyes. You can either use canned air and blow out
the eye holes through the feed neck hole or remove the eye plates with
a 1/16” allen key, pull out the eyes from the mounting holes carefully
and clean them with Q-tips. To test if the eyes work make sure there
is nothing inside the breech and that the bolt is in the back position.