Installation Manual
Objectives part 1ɉ
The purpose of this document is to provide cabling, installation, and bootup instructions of abbbb bbbbb bbb bbb
Everynet gateway in an external or tower environment.b
Terms of use part 2ɉ
● Installer MUST strictly follow installation requirements as conditions of product warranty.b
● Gateways MUST be professionally installed and it is the professional installer’s responsibilityb
to make sure the gateway is properly configured and operated within local country regulatoryb
requirements.b
● There are no operator serviceable parts inside this equipment. Service MUST be provided onlyb
by a qualified service technician approved by gateway manufacturer.b
● Compliance is required with respect to voltage, frequency, and current requirements indicatedb
by manufacturer. Connection to a different power source than those specified may result inb
improper operation, damage to the equipment or pose a fire hazard.b
● PoE power source must have a detachable power cord which has an integral safety ground wireb
connection to a grounded safety outlet.b
● Do not substitute the power cord with one that is not the provided approved type. Never useb
an adapter to connect a 3-wire cable to a 2-wire outlet as this will damage the equipment.b
● The equipment requires the use of the ground wire as a part of the safety certification.b
Modification or misuse may provide a shock hazard that could result in serious injury or death.b
● Contact a qualified electrician or the manufacturer if there are questions about the installationb
prior to connecting the equipment.b
● Protective earthing is provided by approved PoE adapter. Building installation shall provideb
appropriate short-circuit and GFI protection.b
● Protective bonding must be installed in accordance with local national wiring rules andb
regulations.b
● Surge protection and grounding should be used for all outdoor installationsb
● Equipment cabinet located on the bottom of the tower should be grounded to the groundingb
system of the tower.b
● Shielded Category 5 (or above) cabling with drain wire and earth grounding MUST be used forb
all terminations of wired connections.b
● Ethernet cable MUST be properly grounded through the AC ground of the PoE.bb
● Gateway should be grounded to the grounding point on the tower. It is not permitted to groundb
a gateway directly to the tower structures.b
● Lightning arrestor MUST be used to protect for the gateway, lighting protection should beb
grounded to the grounding point on the tower. It is not allowed to ground a lighting protectorb
directly to the tower structures.b
● All coaxial connections should be properly weatherproofed.b
● Gateway should be attached to tower pole using metal ties. Use of plastic / nylon ties isb
prohibited.b
everynet.com 4ɉ