Instructions / Assembly

Figure 3 – KleenSteam II Single
,MFFO4UFBN**4JOHMF$BSUSJEHF
0VUMFU
'/15
*OMFU
'/15
Figure 4 – KleenSteam II Twin
,MFFO4UFBN**5XJO$BSUSJEHF
0VUMFU
'/15
*OMFU
'/15
After the second blow down, turn the steamer power switch to the off position, and turn off 16.
the inlet water at the valve handle on the KleenSteam II unit.
Relieve system pressure by depressing the red relief button on the SR-X head until all air is 17.
expelled and water begins to escape.
Unscrewtheclearbowlandremovethediptubefromthehead.BESURETOREPLACETHE18.
DIPTUBEINIT’SHOLDERONTHEBACKPLATE!
InstallanewSS-10cartridgeintothehead,andscrewthebowlbackintothehead.Hand19.
tighten only!
Turn on the inlet water. Relieve trapped air in the clear bowl by depressing the red relief 20.
button on the SR-X head until all air is expelled and water starts to escape.
Turn the steamer power switch to the on position. Steamer is now ready to be placed back 21.
into service.
REPLACEMENT PARTS
Contact your Everpure dealer for filter cartridges or system replacement parts.
Description Part Number
7CB5Cartridge EV9618-11
SS-10ScaleStick EV9799-02
O-ring for SR-X bowl EV3112-40
Pressure gauge EV3114-09
Dip Tube Assembly EV3080-40
DIMENSIONS AND SPECIFICATIONS
Overall Dimensions 20.5"Wx25.5"Hx7"D
Inlet/Outlet Connections 3/4"FNPT
Shipping Weight (twin cartridge) 28lbs.(12.7Kg)
Operating Weight (twin cartridge) 35lbs.(15.9Kg)
Inlet Water Temperature Limit 100°F(38°C)
Max. Pressure 125psi(8.6bar)
Service Flow Rate 3.5gpm(13.2Lpm)–twincartridge
No electrical service is required