Instructions / Assembly

FILTRATION & PROCESSING SOLUTIONS
QC7I SERIES FILTERS INSTALLATION AND OPERATION GUIDE
SELECTING A MOUNTING LOCATION
1. Give consideration to the weight of the unit when operating (filled with water). Operating weights of the QC7I systems are:
Single - 9 lbs (4 kg)
Twin - 19 lbs (8.5 kg)
Triple - 27 lbs (12 kg)
Quad - 36 lbs (20 kg)
2. The location should allow for:
Minimum clearance of 2.5 inches (6.3 cm) under the
cartridge(s) so it can be lowered for removal
and replacement.
Adequate space for “in” and “out” water line connections.
Be near a drain for flushing and near a 110V outlet if the
accessory (sold separately) Everguard™ Low Pressure Alarm (LPA) is used.
3. If used in conjunction with the Everpure SR-X Feeder, the SR-X should be mounted after the QC7I Series Filter and as
near the equipment as possible. If possible, keep at least 6 inches (15.2 cm) available to the left and the right of the QC7I
System in the event poor quality water conditions require the installation of the optional Everpure E-Series Prefilter.
WARNING: Do not use the MH cartridge in conjunction with the SR-X.
DIMENSIONS
Made in U.S.A.
WATER FILTER
EVERPURE
3072-61
QC7I
120
60
20
EVERPURE
PSI
PSI
0
40
100
80
Inlet
3/8-inch
FNPT
Outlet
3/8-inch
FNPT
27.50 inches
(69.8 cm)
5.60 inches
(14.2 cm)
Inlet
3/4-inch MNPT
Outlet
3/4-inch FNPT
25.26 inches
(64.2 cm)
16.60 inches
(42.1 cm)
Inlet
3/4-inch MNP
T
Outlet
3/4-inch FNPT
29.26 inches
(74.3 cm)
21 inches
(53.3 cm)
Inlet
3/4-inch MNP
T
Outlet
3/4-inch FNPT
29.69 inches
(75.4 cm)
24.60 inches
(62.3 cm)
Single System Twin System Triple System Quad System
Single System Twin System
EVERPURE
®
QC7I SERIES WATER FILTERS
Triple System Quad System
System Tested and Certified by NSF International against NSF/ANSI Standards 42 and 53 for
the reduction of:
Standard No. 42 — Aesthetic Effects Standard No. 53 — Health Effects
Bacteriostatic Effects
Mechanical Filtration
Cyst (MC, MC
2
, MH, MH
2
,
XC, XC
2
only)
Asbestos (MC, MC
2
, MH, MH
2
only)
Chemical Reduction
Taste and Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I (MC, MC
2
,
XC, XC
2
only).