Specification
FOODSERVICE
EV4339-92 SPECIFICATION SHEET
DESIGNED EXCLUSIVELY FOR USE WITH CLARIS REPLACEMENT CARTRIDGES
Coffee and Espresso
Hot Drink Vending
Combi Steamers and Self-Cooking Systems
APPLICATIONS
The system can be operated freestanding,
lying horizontally or mounted vertically.
If mounted vertically to a wall, securely
connect the mounting bracket to the wall
using suitable screws.
Water pressure at the filter system inlet
must not exceed 116 psi (8 bar). A pressure
reducer valve must be installed on the
water supply side of the filter system if the
inlet pressure exceeds 116 psi (8 bar).
Shut-off valve must be installed upstream
of the filter.
Refer to Installation, Operation &
Maintainance Manual for cartridge
flushing and startup.
Change Claris Cartridge when its
pre-calculated water volume has been
reached or at least once a year.
Change cartridges when capacity
is reached.
Always flush the filter cartridge at time of
installation and cartridge change.
Do not use hardness test strips to check for
hardness reduction, please use titration kit
to check for hardness reduction.
INSTALLATION TIPS OPERATION TIPS
Claris Gen2 3/8" QCF Head: EV4339-92
EVERPURE
®
GEN2 3/8" QCF HEAD
Steam Cookers and Ovens
Brewed Iced Tea
Commercial-quality filter head is designed
exclusively to fit Claris filter cartridges
Solid, durable construction is ideal for
foodservice and vending applications
Engineered for durability, strength
and longevity
Corrosion-resistant hardware
Tamper proof bypass settings
FEATURES • BENEFITS
HEAD FEATURES:
Fast change-out - locks with only a
45° turn
Built-in flush port
Auto shut-off
Quick and easy adjustable bypass; key
provided